Journal of Obstetric Anaesthesia and Critical Care

ORIGINAL ARTICLE
Year
: 2022  |  Volume : 12  |  Issue : 2  |  Page : 144--149

Retrospective analysis of the outcome of the anaesthetic procedures in COVID-19 parturient undergoing cesarean delivery in a tertiary care hospital in Delhi, India


Bharti Wadhwa1, Prachi Gaba1, Kapil Chaudhary1, Kirti N Saxena1, Kavita R Sharma1, Mousumi Saha2, Saurabh Gaur1, Pallavi Doda1 
1 Department of Anaesthesia and Intensive Care, Maulana Azad Medical College and Associated Lok Nayak Hospital, New Delhi, India
2 Department of Anaesthesia and Intensive Care, Vardhaman Mahavir Medical College, New Delhi, India

Correspondence Address:
Dr. Mousumi Saha
Department of Anaesthesia and Intensive Care, Maulana Azad Medical College and Associated Lok Nayak Hospital, New Delhi - 110 002
India

Context: The effect of coronavirus disease 2019 (COVID-19) on a parturient undergoing cesarean delivery (CD) is not fully understood. Aims: To evaluate anesthetic management of a COVID parturient undergoing CD. Settings and Design: Tertiary care hospital, retrospective analysis. Methodology: Hospital case record files of COVID-19 parturients who underwent CD were reviewed with respect to clinical presentation, anesthetic technique, peri-operative course, and maternal-fetal outcome. Data Analysis: Continuous variables are reported as mean ± SD or median (range) and categorical variables as numbers (percentages). Results: Hundred COVID-19 parturients underwent CD: Ninety-eight parturients had asymptomatic to mild clinical presentation, whereas two had a severe presentation. Raised liver enzymes, raised D-dimer, and thrombocytopenia were observed in 65, 34, and 11 parturients, respectively. Combined spinal-epidural anesthesia (CSEA), subarachnoid block (SAB), and general anesthesia were administered in 72, 26, and 2 parturients, respectively. Meantime to administration of SAB and CSEA were 23.5 ± 3.2 min and 28.4 ± 2.8 min, respectively. Adequate block height for CD was achieved in all parturients. Post-spinal hypotension that responded promptly to fluids and vasopressors was reported in six parturients. Postoperatively, two parturients required intensive care unit (ICU) care with one maternal mortality. None of the neonates tested positive for COVID-19. Three neonates had a low Appearance, Pulse, Grimace, Activity, and Respiration (APGAR) at 5 min with one neonatal mortality. Conclusions: Neuraxial anesthesia seems to be a safe and preferred anesthetic technique for CD in a COVID-19 parturient. The incidence of post-spinal hypotension is low and responds promptly to treatment. The course of neuraxial anesthesia and the neonatal outcome is unaffected by the COVID-19 status of the patient.


How to cite this article:
Wadhwa B, Gaba P, Chaudhary K, Saxena KN, Sharma KR, Saha M, Gaur S, Doda P. Retrospective analysis of the outcome of the anaesthetic procedures in COVID-19 parturient undergoing cesarean delivery in a tertiary care hospital in Delhi, India.J Obstet Anaesth Crit Care 2022;12:144-149


How to cite this URL:
Wadhwa B, Gaba P, Chaudhary K, Saxena KN, Sharma KR, Saha M, Gaur S, Doda P. Retrospective analysis of the outcome of the anaesthetic procedures in COVID-19 parturient undergoing cesarean delivery in a tertiary care hospital in Delhi, India. J Obstet Anaesth Crit Care [serial online] 2022 [cited 2022 Nov 27 ];12:144-149
Available from: https://www.joacc.com/article.asp?issn=2249-4472;year=2022;volume=12;issue=2;spage=144;epage=149;aulast=Wadhwa;type=0